TY - JOUR
T1 - Long term follow-up of a completely metal free total knee endoprosthesis in comparison to an identical metal counterpart
AU - Breuer, Robert
AU - Fiala, Rainer
AU - Hartenbach, Florian
AU - Pollok, Florian
AU - Huber, Thorsten
AU - Strasser-Kirchweger, Barbara
AU - Rath, Bjoern
AU - Trieb, Klemens
N1 - © 2024. The Author(s).
PY - 2024/9/9
Y1 - 2024/9/9
N2 - Aseptic loosening is a feared and not yet fully-understood complication of total knee arthroplasty (TKA). Hypersensitivity reactions may be the underlying cause within some susceptible patients. Metal-free implants have been developed as a possible solution. The aim of this prospective, observational long-term study was the assessment of a completely metal-free ceramic knee replacement system compared to its identical metal counterpart 8 years after implantation, conducted as a follow-up of a previous report. A total of 88 patients (mean age 69 years) were enrolled in this prospective, observational long-term 8-year follow-up study. The "ceramic group" with a completely metal-free total knee replacement system was compared to the "conventional group" with an identical metal TKA system at the final follow-up. Clinical assessment included Knee Society Score (KSS), Oxford Knee Score (OKS), European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-L), European Quality of Life 5 Dimension Visual Analogue Scale (EQ-VAS) and High Activity Arthroplasty Score (HAAS) as well as perioperative or postoperative complications and need for revision. The tibial/femoral positioning, signs of periprosthetic fissures/fractures or radiolucent lines were documented radiographically. All postoperative clinical scores in the ceramic group primarily improved from baseline to 4-year follow-up, but then decreased at the final 8-year follow-up. At the final follow-up, statistically non-significant differences were found in comparison of both groups for the KSS (ceramic: 166 ± 31, conventional: 162 ± 29; p > 0.05), OKS (ceramic: 37, conventional: 39; p > 0.05), EQ-VAS (ceramic: 77 ± 17, conventional: 72 ± 18; p > 0.05), and HAAS (ceramic: 8.29 ± 3.32, conventional: 9.28 ± 4.44; p > 0.05). A significant difference was found for EQ-5D-L (ceramic: 0.819 ± 0.284, conventional: 0.932 ± 0.126; p ≤ 0.05). Progressive radiolucent lines have been found around the uncemented tibial stem (0.8 mm at initial diagnosis (mean 19 months); 1.3 mm at 4-year follow-up; 1.6 mm at 8-year follow-up) without any clinical signs of loosening. One revision surgery was performed after a traumatic polyethylene inlay-breakage. No allergic reactions could be detected. The used ceramic TKA system meets the functional performance standards of an established identical metal TKA system after an 8-year follow-up period, offering a safe option for patients with prior hypersensitivity reactions to metallic materials. Full cementation of ceramic components is recommended.
AB - Aseptic loosening is a feared and not yet fully-understood complication of total knee arthroplasty (TKA). Hypersensitivity reactions may be the underlying cause within some susceptible patients. Metal-free implants have been developed as a possible solution. The aim of this prospective, observational long-term study was the assessment of a completely metal-free ceramic knee replacement system compared to its identical metal counterpart 8 years after implantation, conducted as a follow-up of a previous report. A total of 88 patients (mean age 69 years) were enrolled in this prospective, observational long-term 8-year follow-up study. The "ceramic group" with a completely metal-free total knee replacement system was compared to the "conventional group" with an identical metal TKA system at the final follow-up. Clinical assessment included Knee Society Score (KSS), Oxford Knee Score (OKS), European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-L), European Quality of Life 5 Dimension Visual Analogue Scale (EQ-VAS) and High Activity Arthroplasty Score (HAAS) as well as perioperative or postoperative complications and need for revision. The tibial/femoral positioning, signs of periprosthetic fissures/fractures or radiolucent lines were documented radiographically. All postoperative clinical scores in the ceramic group primarily improved from baseline to 4-year follow-up, but then decreased at the final 8-year follow-up. At the final follow-up, statistically non-significant differences were found in comparison of both groups for the KSS (ceramic: 166 ± 31, conventional: 162 ± 29; p > 0.05), OKS (ceramic: 37, conventional: 39; p > 0.05), EQ-VAS (ceramic: 77 ± 17, conventional: 72 ± 18; p > 0.05), and HAAS (ceramic: 8.29 ± 3.32, conventional: 9.28 ± 4.44; p > 0.05). A significant difference was found for EQ-5D-L (ceramic: 0.819 ± 0.284, conventional: 0.932 ± 0.126; p ≤ 0.05). Progressive radiolucent lines have been found around the uncemented tibial stem (0.8 mm at initial diagnosis (mean 19 months); 1.3 mm at 4-year follow-up; 1.6 mm at 8-year follow-up) without any clinical signs of loosening. One revision surgery was performed after a traumatic polyethylene inlay-breakage. No allergic reactions could be detected. The used ceramic TKA system meets the functional performance standards of an established identical metal TKA system after an 8-year follow-up period, offering a safe option for patients with prior hypersensitivity reactions to metallic materials. Full cementation of ceramic components is recommended.
KW - Humans
KW - Arthroplasty, Replacement, Knee/adverse effects
KW - Female
KW - Aged
KW - Male
KW - Follow-Up Studies
KW - Knee Prosthesis/adverse effects
KW - Middle Aged
KW - Prospective Studies
KW - Prosthesis Design
KW - Quality of Life
KW - Prosthesis Failure
KW - Ceramics
KW - Knee Joint/surgery
KW - Aged, 80 and over
KW - Postoperative Complications/etiology
KW - Metals/adverse effects
KW - Treatment Outcome
UR - http://www.scopus.com/inward/record.url?scp=85203312707&partnerID=8YFLogxK
UR - https://pubmed.ncbi.nlm.nih.gov/39251687/
UR - https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11384776/
UR - https://www.mendeley.com/catalogue/e9570500-399b-32b0-a07e-e77cd29cc429/
U2 - 10.1038/s41598-024-71256-y
DO - 10.1038/s41598-024-71256-y
M3 - Article
C2 - 39251687
SN - 2045-2322
VL - 14
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 20958
ER -