At-line quantitative profiling of monoclonal antibody products during bioprocessing using HPLC-MS

Katharina Böttinger, Christian G. Huber* (Corresponding author), Wolfgang Esser-Skala, Marius Segl, Christoph Herwig

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

(1) Background: The N-glycosylation profile as well as the subunit assembly of monoclonal antibodies (mAbs) are strongly dependent on manufacturing conditions and thus need to be monitored during the bioprocess. Commonly, mAbs are characterized downstream of the fermentation process applying different analytical techniques like released glycan analysis, peptide mapping, or subunit profiling. However, these procedures are time-consuming and difficult to perform in real-time. (2) Methods: We applied a simple HPLC-MS workflow with minimal sample preparation to characterize mAb product quality at the intact protein level at different time points during fermentation. After harvest, the cell culture medium was centrifuged briefly. The supernatant containing the fermentation product was diluted and immediately subjected to HPLC-MS analysis. (3) Results: Besides the product of interest (mAb), the fermentation broth contained misassembled variants, mostly light chain and light chain dimer. The mAb's glycosylation profile changed over time showing an increase in galactosylated variants with G0F/G1F being the most abundant glycoform at all time points of fermentation. Furthermore, expressed protein species were relatively and absolutely quantified. The workflow was very robust despite analyzing a highly complex matrix. Relative standard deviations for retention times were below 0.5% for both intra and inter-day comparison, whereas relative procedural standard deviations for quantification of the different protein species ranged between 7 and 13%. (4) Conclusions: This approach allows for reliable analysis of product profiles of monoclonal antibody species including misassembled subunits and glycosylation variants directly from fermentation broth using a fast and robust HPLC-MS workflow
Original languageEnglish
Article number339813
Number of pages13
JournalAnalytica Chimica Acta
Volume1207
Issue number1207
DOIs
Publication statusPublished - 15 May 2022

Bibliographical note

Publisher Copyright:
© 2022 The Authors

Keywords

  • Dilute-and-shoot
  • Fermentation
  • Glycosylation
  • Monoclonal antibody
  • Quantification

Fields of Science and Technology Classification 2012